Bulk Fiber MultiMode/02str, OM1, OFNR, LT/Gel, OutDoor, BLK - Per Foot
You Have:0 Items
Total:$0.00

User login

Bulk 2 Strand OM1 Fiber, MM, LT/Gel, OutDoor, OFNR - Per Foot

High tensile strength, crush resistant and a small diameter design make this bulk fiber perfect for outdoor use. 

SKU:
91-803910-0000K

Specifications

Fiber Performance       Mechanical and Environmental  
Fiber Code
OFNR
Industry Standard Designation
OFN-FT4
Core/Cladding Diameter (μm)
9/125
Wavelength (nm)
850/1300
Fiber Count
2
Operating Temperature
-40°C to +75°C
Storage Temperature
-60°C to +85°C
Installation Temperature
(actual temp. of cable)
-20°C to +60°C
Flame Retardancy
UL Listed Type OFNR
Installation and Operating Characteristics       Cable Characteristics  
  Installation Operating
Max Tensile Load
135 lbs
n/a
Min Bend Radius
(4 in)
(6 in)
Jacket Color
Black
Jacket Material
Fluoropolymer
Buffer Material
Soft Plenum
Cable Weight
110 lb/km (74 lbs/1000')
Cable Diameter
10.2 mm

Applications

  • Used in trunking, LAN and distribution applications where small size, lightweight, and versatile installation capability are required between floors in non-plenum spaces
  • Ideal configuration for a single termination point requiring multiple fibers
  • Broad design selection allows for mix and match of ber components to specic networking applications.

Features

  • High performance components and construction
  • High specific strength-to-weight ratio and compact cable design for limited conduit space and tight bends in long cable pulls
  • Low cable plant maintenance, ease of installation.
  • UV resistant riser rated polymer used for jacket and loose tubes
  • Lower installed cost
  • High performance tight-buffered coating on each fiber for environmental and mechanical protection
  • High crush resistance may eliminate the need for innerduct
  • 900 μm buffer eliminates the need for costly and time-consuming installation of fanout kits or pigtail splices because connectors terminate directly to the fiber.
  • UL Listed in accordance with NEC section 770.179(a) for use in ducts, plenums and air-handling spaces